SmartFan TachScan-3 is a digital fan speed alarm that monitors the tach pulses from up to three DC or AC fans or blowers and provides OR’d pass/fail signals. TachScan-3 is compatible with any fan that provides open collector or voltage source tach pulses. Three trigger speeds are selectable by jumper. If the speed of any air mover falls below the trigger speed, alarm signals are generated. Alarm signals can drive LEDs, logic, optical isolators or MOS Relays.
 

Features

  • Accepts any supply voltage from 6 to 60 VDC and distributes power to DC fans through the same header used to sense tach pulses. It can also be used to power the DC tach circuits built into AC fans.
  • Three inputs monitor fans with any open collector or voltage source tach pulses.
  • P/N 030M320 provides simultaneous NO and NC open collector outputs from optical isolators which can sink up to 1.0 mA to drive logic circuits.
  • P/N 030M320R provides simultaneous NO and NC isolated outputs from a Dual-Pole MOS Relay which can sink up to 100 mA to drive heavy loads.
  • Jumper sets trigger speed to 1,000, 2,000 or 4,000 PPM.
  • Can drive two single LEDs or one bi-colored LED.
  • Compatible with any SmartFan speed controller.
  • Small size of 3.5” X 1.5” permits mounting in small spaces within fan trays, etc.
 
SPECIFICATIONS
 
Part Number
Isolated Alarm Sinking Current
Supply Voltage Range
Maximum Input Current
Maximum Output Current to Any Fan
 
030M320
030M320R
1 mA
100 mA
 
6 to 60 VDC
2.50 Amps
2.50 Amps
H116
Hardware Pack
Note: Maximum operating temperature is 65°C
 
INSTALLATION
 
Fan Connections
For three wire DC fans operating at supply voltages between 6.0 and 60.0 VDC, TachScan-3 distributes power to the fans in addition to accepting tachometer pulses from the fans. Connect the fan wires to J1, J2 and J3 using the suggested hardware, or equivalent. For applications using less than three fans, any of the three connectors (J1, J2, J3) can be used to monitor tachometer signals. The fan wires are usually color coded with red for +, black for - and white or yellow for A (alarm). Input current must not exceed 2.5 Amps.
 
CONNECTIONS / JUMPERS

Figure 1 Wiring Diagram

Click on drawing to view large scale version

 
AC Fan Alarm Monitoring
TachScan-3 cannot distribute AC power to AC fans. AC fans usually have 5 wires, 2 for power and 3 for the tachometer pulse circuit. Connect the AC fan power leads to the rated source of power. Connect the tachometer pulse leads (+, -, tach pulse) to J1, J2, and J3. TachScan-3 distributes power to run the tachometer pulse circuits within the fans. Apply a DC voltage at J7 as specified by the fan manufacturer for the tachometer pulse circuits.
 
Use with a SmartFan Speed Controller
Because of the wide range of power supply voltages that may be connected to J7, TachScan-3 may be used with any DC SmartFan speed controller. The power output of the speed controller that would otherwise be connected directly to the fan load is instead connected to J7 (See figure 2). TachScan-3 in turn distributes this power to the fans.
 
SUGGESTED CONNECTING HARDWARE
 
Ref. Desc.
Header on Board (1)
H115 Hardware Pack
Quantity
Description
Manufacturer (1)
Part Number (1)
J1, J2 J3
22-29-2031
3
9
Housing Terminal (gold)
Molex
Molex
22-01-3037
08-55-0102
J6, J8
22-29-2041
2
8
Housing Terminal (gold)
Molex
Molex
22-01-3047
08-55-0102
J7
22-29-2021
1
2
Housing Terminal (gold)
Molex
Molex
22-01-2027
08-55-0102
4
PCB Support
Richco
CBS-4-19
 
(1) or equivalent
 
   
Copyright © 2002 European Thermodynamics Ltd. All rights reserved.